Galvin CliniMix® BS Lead Safe™ Service Cartridges are desgined for CliniMix® Lead Safe™ CMV2 and is complete with strainer, non-return valve and flow restrictor.

 

 

Technical Information

  • WaterMark: AS 4032.4 Lic. WMKA21989
  • Working Pressure Range (kPa): 20 Min - 500 Max
  • Working Pressure Range (°C): 5 Min - 85 Max
  • Nominal Flow Rate (LPM): 4
  • Construction: Lead Safe™ Brass
  • Finish: Brass

This product is compatible with

  • 100.41.20.20 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Proximity Sensor, Chrome Face Plate
  • 100.81.20.20 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Proximity Sensor, Chrome Face Plate with Anti-Ligature Outlet
  • 100.41.21.20 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Proximity Sensor, Chrome Face Plate with Temp Monitoring
  • 100.41.20.30 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Proximity Sensor, Glass Face Plate
  • 100.41.21.30 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Proximity Sensor, Glass Face Plate with Temp Monitoring
  • 100.41.10.20 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Wave On/Off, Chrome Face Plate
  • 100.81.10.20 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Wave On/Off, Chrome Face Plate with Anti-Ligature Outlet
  • 100.41.11.20 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Wave On/Off, Chrome Face Plate with Temp Monitoring
  • 100.41.10.30 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Wave On/Off, Glass Face Plate
  • 100.41.11.30 CliniMix® Lead Safe™ CMV2 Wall Mtd Handsfree POU, Wave On/Off, Glass Face Plate with Temp Monitoring

Environmental Sustainability

We are ISO 14001 certified and take sustainability seriously. Our products are environmentally responsible designed to be healthier for users, save water and/or energy, and minimise carbon footprint. Our target is to reduce our carbon footprint by 25%, and the use of non-recyclable/non-compostable materials across the company (e.g. plastics) by 50%.

Warranty

Galvin Engineering products are covered under our Manufacturer's Warranty. Galvin Engineering products must be installed in accordance with the installation instructions and in accordance with AS 3500 and NCC Volume Three, relevant Australian Standards and local authorities applicable to product being installed. Water and electrical supply conditions must also comply to the applicable national and/or state standards, failing to comply with these provisions may void the product warranty and affect performance of the product.

Please visit www.galvinengineering.com.au to view the full warranty, our Installation Compliance and Maintenance & Cleaning information as well as any other additional information.

While all reasonable care has been taken in compiling the information in this document, the designs, dimensions and products shown are indicative only and should not be relied upon without our prior approval. Due to our policy of continuous development, we reserve the right to alter any details of specifications or products without notice. All information, drawings, technical specifications and product designs remain the property of Galvin Engineering Pty Ltd.

Our Lead Safe™ product range is compliant with the Lead Free Requirements of the NCC 2022 Vol. Three, Clause A5G4(2) and NSF/ANSI 372.