New state of the art Galvin CliniMix® Lead Safe™ Inwall Thermostatic Progressive Shower Mixer with GalvinCare® Handle for shower applications. Specifically designed for mental health and health care facilities featuring an easy to operate on/off temperature control and option to be set to a thermostatically controlled temperature of 48°C maximum. Suitable for high and low pressure systems, reliable CliniMix® Lead Safe Inwall Thermostatic Progressive Shower Mixer is water conversing and cost-effective. 

Features
  • Manufactured using Lead Safe™ DZR Brass with less than 0.25% lead content*
  • Has a unique thermal disinfection bypass feature (kit sold separately) 
  • Reduces risk of Legionella growth by mixing water close to point of discharge and minimising stagnant warm water
  • Minimises dirt build up and is fast and easy to clean due to its smooth internal and external design 
  • Can be set to a thermostatically controlled water temperature of 48°C
  • Water flow always start from cold for safe usage
  • All servicing and commissioning can be done without removing the device. Easy to access isolators helps to minimise the time of commissioning and maintenance.
  • Rapid shut down in the event of cold or hot water supply failure
 

Technical Information

  • WaterMark: AS 4032.4 Lic. WMKA21989
  • Inlet: 1/2" BSP - Male
  • Outlet: 1/2" BSP - Male
  • Headwork: Thermostatic Mixing Valve (TMV)
  • Working Pressure Range (kPa): 20 Min - 500 Max
  • Supply Temperature Range (°C): 5 Min - 85 Max
  • Minimum Temp. Differential (Between Supply and Outlet Temperature) (°C): 10 
  • Adjustable Temperature Range (°C): 35 Min - 48 Max 
  • Permitted Supply Pressure Variation: 10:1 
  • Factory Set Thermostatic Temperature (°C): 41 
  • Minimum Flow Rate for Stable Outlet Temp. (LPM): 6  
  • Maximum Flow Rate (LPM): 18 @ 300kPa
  • Construction: Lead Safe™ DZR Brass*
  • Finish: Chrome

Optional Extras

  • WM-PMSKIT CliniMix® Inwall Shower Disinfection Plug Kit

Spare Parts

  • 100.90.70.20 CliniMix® BS Lead Safe™ Thermostatic Cartridge Assembly for Progressive Mixer
  • 100.90.72.20 CliniMix® Lead Safe™ Progressive Shower Non Return Valve & Strainer Assembly (Pair)

Superseding Products

  • WM-TMVPMSCS CliniMix® CP-BS Inwall Thermo Progressive Shower Mixer with GalvinCare® Handle W&C

Environmental Sustainability

We are ISO 14001 certified and take sustainability seriously. Our products are environmentally responsible designed to be healthier for users, save water and/or energy, and minimise carbon footprint. Our target is to reduce our carbon footprint by 25%, and the use of non-recyclable/non-compostable materials across the company (e.g. plastics) by 50%.

Warranty

Galvin Engineering products are covered under our Manufacturer's Warranty. Galvin Engineering products must be installed in accordance with the installation instructions and in accordance with AS 3500 and NCC Volume Three, relevant Australian Standards and local authorities applicable to product being installed. Water and electrical supply conditions must also comply to the applicable national and/or state standards, failing to comply with these provisions may void the product warranty and affect performance of the product.

Please visit www.galvinengineering.com.au to view the full warranty, our Installation Compliance and Maintenance & Cleaning information as well as any other additional information.

While all reasonable care has been taken in compiling the information in this document, the designs, dimensions and products shown are indicative only and should not be relied upon without our prior approval. Due to our policy of continuous development, we reserve the right to alter any details of specifications or products without notice. All information, drawings, technical specifications and product designs remain the property of Galvin Engineering Pty Ltd.

Our Lead Safe™ product range is compliant with the Lead Free Requirements of the NCC 2022 Vol. Three, Clause A5G4(2) and NSF/ANSI 372.

In the absence of a legal or industry definition of anti-ligature or ligature resistant products, when we use these terms, we are referring to products that are designed and manufactured with the intention of reducing the risk of ligature attachment to the product(s). Galvin Engineering Pty Ltd will always endeavour to design and test our anti-ligature product(s) to reduce the risk of product ligature attachment that may result in serious injury or death. Whilst all reasonable measures are taken at the time of design, the anti-ligature design of the products are not intended to and will not:
a. Replace protective measures that need to be taken in the specific circumstances of usage;
b. Substitute the need for supervision of those who may be at risk;
c. Protect and or prevent those at risk against any self-harm instances that may occur when installed; and
d. Protect and or prevent injury when the risks where unknown to us at the time of the design of the product(s).
Galvin Engineering Pty Ltd does not offer and does not represent or warrant that any product(s) for sale are ligature-free. Therefore, Galvin Engineering will not be liable for any claims, loss, or damages arising from ligature attachment on our products. It is the purchaser's responsibility to ensure that products purchased and installed are suitable for the environments in which they are installed, and suitable supervision and protective measures are in place to protect those at risk.