Skip to main content

Specification Data Sheet

The Galvin Specialised Flowmatic® cell call electronic activated assembly, provides the complete vandal and ligature resistant solution. It is designed for mains pressure flushing installations. 

Exposed Plate

  • 4mm thick brushed stainless steel with 4mm radius corners
  • Designed for front fixing

Controller Requirements

  • The control box and sensors must be mounted within 3 metres of the supply valve.
  •  A 220 - 240V 50Hz 10 amp general purpose outlet must be supplied within 1 metre of the control box.
  •  All plumbing must comply with AS/NZS 3500.

Pan Function

  • Pressing the cell call button on the stainless steel plate activates the flusher.

Flush Valve for Pan Flow Rate Requirement

  • Flow Rate: Minimum of 1.5 litres per second to flush valve
  • Connection size on valve 25mm BSP
  • All plumbing and installation must be carried out in accordance with AS/NZS 3500

Note: No flush pipe provided.

General

  • Cabling: Is supplied for the cell call button, solenoid and transformer.
  • Controller: Galvin Specialised controller is a 24V AC electronic control system. Depending on the settings programmed, the solenoids will open for a specific time once the appropriate button is pressed.
  • Australian Made; therefore, spare parts and support are available locally, reducing maintenance and downtime costs

Technical Information

  • WaterMark AS/NSZ 1172.2 Lic. WMK26456
  • Inlet: 1" BSP - Female
  • Outlet: 2" BSP - Male
  • Headwork: Solenoid
  • Activation: Push Button
  • Working Pressure Range (kPa): 70 Min - 500 Max
  • Working Temperature Range (°C): 2 Min - 40 Max
  • Finish: Stainless Steel

Environmental Sustainability

We are ISO 14001 certified and take sustainability seriously. Our products are environmentally responsible designed to be healthier for users, save water and/or energy, and minimise carbon footprint. Our target is to reduce our carbon footprint by 25%, and the use of non-recyclable/non-compostable materials across the company (e.g. plastics) by 50%.

Warranty

Galvin Engineering products are covered under our Manufacturer's Warranty. Galvin Engineering products must be installed in accordance with the installation instructions and in accordance with AS 3500 and NCC Volume Three, relevant Australian Standards and local authorities applicable to product being installed. Water and electrical supply conditions must also comply to the applicable national and/or state standards, failing to comply with these provisions may void the product warranty and affect performance of the product.

Please visit www.galvinengineering.com.au to view the full warranty, our Installation Compliance and Maintenance & Cleaning information as well as any other additional information.

While all reasonable care has been taken in compiling the information in this document, the designs, dimensions and products shown are indicative only and should not be relied upon without our prior approval. Due to our policy of continuous development, we reserve the right to alter any details of specifications or products without notice. All information, drawings, technical specifications and product designs remain the property of Galvin Engineering Pty Ltd.